[{"@context":"https:\/\/schema.org\/","@type":"Article","@id":"https:\/\/www.framil.cz\/protokol-o-urceni-vnejsich-vlivu-je-potrebny-pro-provadeni-revize-elektroinstalace\/#Article","mainEntityOfPage":"https:\/\/www.framil.cz\/protokol-o-urceni-vnejsich-vlivu-je-potrebny-pro-provadeni-revize-elektroinstalace\/","headline":"Protokol o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f je pot\u0159ebn\u00fd pro prov\u00e1d\u011bn\u00ed revize elektroinstalace","name":"Protokol o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f je pot\u0159ebn\u00fd pro prov\u00e1d\u011bn\u00ed revize elektroinstalace","description":"Sou\u010d\u00e1st\u00ed v\u00fdstavby rodinn\u00e9ho domu je projektov\u00e1 dokumentace a k t\u00e9 je zapot\u0159eb\u00ed i Protokol o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f. Ten [&hellip;]","datePublished":"2025-08-13","dateModified":"2025-08-13","author":{"@type":"Person","@id":"https:\/\/www.framil.cz\/author\/#Person","name":"","url":"https:\/\/www.framil.cz\/author\/","identifier":1,"image":{"@type":"ImageObject","@id":"https:\/\/secure.gravatar.com\/avatar\/9d25b0af9840660883a67790aa4f595ddc226aa4680c4cf7bc03a25c14fcef85?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9d25b0af9840660883a67790aa4f595ddc226aa4680c4cf7bc03a25c14fcef85?s=96&d=mm&r=g","height":96,"width":96}},"publisher":{"@type":"Organization","name":"framil.cz","logo":{"@type":"ImageObject","@id":"\/logo.png","url":"\/logo.png","width":600,"height":60}},"image":{"@type":"ImageObject","@id":"https:\/\/www.framil.cz\/wp-content\/uploads\/electrician-1696757_640_9.jpg","url":"https:\/\/www.framil.cz\/wp-content\/uploads\/electrician-1696757_640_9.jpg","height":0,"width":0},"url":"https:\/\/www.framil.cz\/protokol-o-urceni-vnejsich-vlivu-je-potrebny-pro-provadeni-revize-elektroinstalace\/","wordCount":382,"articleBody":"   Sou\u010d\u00e1st\u00ed v\u00fdstavby rodinn\u00e9ho domu je projektov\u00e1 dokumentace a k t\u00e9 je zapot\u0159eb\u00ed i Protokol o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f. Ten se vztahuje v dan\u00e9m objektu ke zhotoven\u00ed elektroinstalace a vytv\u00e1\u0159\u00ed soupisku \u201evn\u011bj\u0161\u00edch vliv\u016f\u201c, kter\u00e9 mohou nep\u0159\u00edzniv\u011b ovlivnit elektrick\u00e1 za\u0159\u00edzen\u00ed. Zjednodu\u0161en\u011b \u0159e\u010deno se jedn\u00e1 o seznam jev\u016f, kter\u00e9 na elektroinstalaci negativn\u011b p\u016fsob\u00ed, a \u010d\u00edm nebezpe\u010dn\u011bj\u0161\u00ed prost\u0159ed\u00ed, t\u00edm krat\u0161\u00ed tak\u00e9 mus\u00ed b\u00fdt (nebo m\u011bl by b\u00fdt) interval mezi prov\u00e1d\u011bn\u00fdmi revizemi.Revize elektroinstalace m\u016f\u017ee b\u00fdt povinn\u00e1 \u010di nepovinn\u00e1, z\u00e1le\u017e\u00ed na typu objektu a jeho u\u017e\u00edv\u00e1n\u00ed, p\u0159i\u010dem\u017e intervaly mezi jednotliv\u00fdmi revizemi se mohou pohybovat od jednoho roku do p\u011bti let. V norm\u011b Protokolu o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f, eventu\u00e1ln\u011b v revizn\u00ed zpr\u00e1v\u011b, by tak\u00e9 \u010detnost reviz\u00ed m\u011bla b\u00fdt zakotvena. Revizn\u00ed elektrik\u00e1\u0159 v\u0161ak m\u016f\u017ee revize prov\u00e1d\u011bt i v krat\u0161\u00edch intervalech, jestli\u017ee to vy\u017eaduje aktu\u00e1ln\u00ed situace. Vn\u011bj\u0161\u00ed vlivy jsou v Protokolu o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f zakotveny v k\u00f3dech. P\u00edsmeno A ozna\u010duje vn\u011bj\u0161\u00ed vlivy prost\u0159ed\u00ed, p\u00edsmeno B vyu\u017e\u00edv\u00e1n\u00ed objektu a p\u00edsmeno C vliv konstrukce budovy. Kup\u0159\u00edkladu vlivem konstrukce budovy je pou\u017eit\u00fd stavebn\u00ed materi\u00e1l a k vliv\u016fm vyu\u017e\u00edv\u00e1n\u00ed objektu pat\u0159\u00ed vliv lidsk\u00e9 obsluhy, kontakt \u010dlov\u011bka s potenci\u00e1lem zem\u011b, elektrick\u00fd odpor lidsk\u00e9ho t\u011bla a d\u00e1le pak p\u0159edm\u011bty, kter\u00e9 se v budov\u011b vyskytuj\u00ed, zda jde nap\u0159. o ho\u0159lavinu \u010di v\u00fdbu\u0161ninu. Nejv\u011bt\u0161\u00ed pod\u00edl vliv\u016f tvo\u0159\u00ed vn\u011bj\u0161\u00ed vlivy prost\u0159ed\u00ed, ozna\u010den\u00e9 p\u00edsmenem A. Tam pat\u0159\u00ed nap\u0159\u00edklad atmosf\u00e9rick\u00e9 vlivy, teplota prost\u0159ed\u00ed, nadmo\u0159sk\u00e1 v\u00fd\u0161ka, p\u0159\u00edpadn\u00e1 vysok\u00e1 vlhkost a v\u00fdskyt vody, vliv koroze, mechanick\u00e9ho nam\u00e1h\u00e1n\u00ed \u010di v\u00fdskyt magnetick\u00e9ho a elektrick\u00e9ho pole. D\u00e1le do hry mohou promlouvat rostliny, \u017eivo\u010dichov\u00e9 a pl\u00edsn\u011b, slune\u010dn\u00ed z\u00e1\u0159en\u00ed, proud\u011bn\u00ed vzduchov\u00e9 hmoty a bou\u0159kov\u00e1 \u010dinnost (v\u00fdskyt blesk\u016f). N\u011bkter\u00e9 nebezpe\u010dn\u00e9 vlivy mus\u00ed b\u00fdt uvedeny i v dokumentaci po\u017e\u00e1rn\u00ed ochrany, p\u0159\u00edpadn\u011b v dokumentaci o ochran\u011b prostor p\u0159ed exploz\u00ed.                                                                                                                                                                                                                                                                                                                                                                                                  "},{"@context":"https:\/\/schema.org\/","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Protokol o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f je pot\u0159ebn\u00fd pro prov\u00e1d\u011bn\u00ed revize elektroinstalace","item":"https:\/\/www.framil.cz\/protokol-o-urceni-vnejsich-vlivu-je-potrebny-pro-provadeni-revize-elektroinstalace\/#breadcrumbitem"}]}]